Reliable monitoring
Of the brake function and wear with just one measurement system.
Individual planning
Of the wear-based maintenance intervals because the /DUE diagnostic unit continuously determines the brake's working air gap.
Just one purchase
Because the measurement system itself works contactlessly and without wear.
The measurement system works contactlessly based on the eddy current principle; high-frequency alternating current flows through the sensors. The electromagnetic field induces eddy currents in the pressure plate, which change the sensor's AC resistance. The evaluation unit converts this change in impedance to an electrical signal (4 – 20 mA) that is proportional to the brake's working air gap.
The brake function is monitored using digital signals (NO contacts), and digital outputs (NC contacts) are used to indicate that the wear limits have been reached. Current outputs also allow continuous monitoring of brake wear.
In addition to the outputs, LEDs on the evaluation unit also indicate the function and wear of every partial brake.
The following tables list the technical data of the diagnostic units for installation in the motor wiring space and the sensors installed in the coil body.
Evaluation unit | DUE-1K-00 For BE.. brakes | DUE-2K-00 For BF.. brakes | ||
Signal outputs (2 channels) | BE.. brake Out1: 4 – 20 mA FCT1: DC 24 V (150 mA) WEAR1: DC 24 V (150 mA) | Partial brake 1 for BF.. brakes Out1: 4 – 20 mA FCT1: DC 24 V (150 mA) WEAR1: DC 24 V (150 mA) Partial brake 2 for BF.. brakes Out2: 4 – 20 mA FCT2: DC 24 V (150 mA) WEAR2: DC 24 V (150 mA) | ||
Current consumption | Max. | mA | 190 | 360 |
Min. | mA | 40 | 80 | |
Supply voltage | DC 24 V (± 15%) | |||
Electromagnetic compatibility | DIN EN 61800‑3 | |||
Operating temperature range for the evaluation unit | -40 to +105 °C | |||
Humidity | ≤ 90% relative humidity | |||
Degree of protection | IP20 (max. IP66 in closed terminal box) |
Sensors | DUE-d6-00 | DUE-d8-00 |
Degree of protection | IP66 | IP66 |
Operating temperature range of sensor and cable | -50 to +150 °C | -50 to +150 °C |
The /DUE diagnostic unit is available with the proven type DR.. motors, as well as DR.. motors with the new double brake. These combinations are currently implemented.
Motor type DRN.. | BE.. brake type |
80MK, 80M, 90S, 90L, 100L, 100LS, 112M, 132S, 132M, 132L | BE1, BE2, BE5, BE11 |
132M, 132L, 160M, 160L, 180M, 180L | BE20 |
160M, 160L, 180M, 180L, 200L, 225S, 225M, | BE30, BE32 |
200L, 225S, 225M, 250M, 250ME, 280S, 280M, | BE60, BE62 |
250M, 250ME, 280S, 280M, 315S, 315M, 315ME, 315L, 315H | BE120, BE122 |